Johnson Service Bulletin SB-1008 - Shorted Stop Switch

Issued March 5, 1964, this bulletin describes an intermittent stop-switch short on certain 1964 Johnson outboards and the recommended replacement or temporary repair procedure.

Johnson Motors Service Bulletin factory letterhead
SB-#1008

March 5, 1964

SUBJECT:   SHORTED STOP SWITCH - PART NO. 379638

ON ENGINES:1964 - MODELS9½ HP
18 HP
28 HP
40 HP (Manual start)

This bulletin calls your attention to possible shorting of the stop switch on any of the above listed 1964 models. Several examples of this condition have already been brought to our attention.

Factory cutaway drawing of stop switch, showing rubber cover, socket, movable contact, nylon housing, stationary contacts, and electrical leads
Fig. 1. Cutaway drawing of Stop Switch

In this particular instance, the switch becomes shorted as follows:
The moveable contact slips out of its retaining socket in the rubber switch cover and falls against the two stationary contacts - shorting the ignition system. The engine will then cut-out intermittently or stop completely, depending on how the moveable contact is laying in the switch. A continual short between the two stationary contacts would also prevent re-starting once the engine stopped.

The recommended corrective measure for this problem is switch replacement; however, in instances where a replacement switch is not available, the defective switch can be repaired and used temporarily while a new switch is being ordered. Repair is accomplished by removing the rubber switch cover, inserting the moveable contact back in its socket and re-assembling the switch.

JOHNSON MOTORS
Robert Compton
Administrative Assistant

RC:eb