October, 1965 SB-#1071

SUBJECT:   TANK TESTING THE V4ML-12 100 H.P. MOTOR

ON MODELS:   V4ML-12 100 H.P. ENGINE

Figure 1: gearcase extension cover plate
Figure 1
Figure 2: test tank water level within 11 inches of bracket top
Figure 2

Please be advised that if it should become necessary to run a V4ML-12 100 H.P. engine in a test tank for any purpose, strict adherence to the following is necessary to avoid overheating these engines:

  1. Before putting the engine into the test tank, remove the cover plate and gasket located on the gearcase extension (Figure 1).
  2. Install test wheel, part number 381283, and put engine in test tank.
  3. Before running engine, be certain that the water level in the test tank is within 11" of the top face of the test tank mounting bracket (Figure 2).

UNDER NO CIRCUMSTANCES SHOULD THE ENGINE BE STARTED IF THE WATER LEVEL IN THE TEST TANK IS MORE THAN 11" BELOW THE TOP FACE OF THE TEST TANK MOUNTING BRACKET!

PAGE 2      SERVICE BULLETIN SB-#1071
JOHNSON MOTORS, DIVISION OF OUTBOARD MARINE CORPORATION, WAUKEGAN, ILLINOIS 60086

──── CAUTION ────

THIS ENGINE SHOULD NOT BE RUN AT SPEEDS IN EXCESS OF 3000 RPM FOR MORE THAN 30 SECOND INTERVALS UNLESS ADDITIONAL COOLING WATER IS SUPPLIED TO THE GEARCASE EXTENSION THROUGH USE OF A HOSE AND ADAPTER INSTALLED IN PLACE OF THE EXTENSION COVER PLATE.

A suitable adapter for this purpose can be fabricated from plate #308308, a suitable length of 5/8" I.D. hose, and the necessary clamps and fittings to attach the hose to an external water supply.

The pressure of any external water supply used for this purpose should not exceed 10 psi.

JOHNSON MOTORSN. Peter HansenAdministrative Assistant

NPH:rs

NOTE: Post on your VM-100 HP Index, under the heading "Miscellaneous".

Historical parts and service reference

381283 - test wheel. 308308 - plate used to fabricate a supplemental cooling-water adapter. This bulletin applies to the V4ML-12 100 H.P. engine.

Factory safety limits: water no more than 11 inches below the mounting-bracket top face; above 3,000 RPM, no more than 30 seconds without supplementary cooling; external cooling supply not over 10 psi.