Johnson Service Bulletin SB-1075 - Grounded Reverse Coil Lead

November 1965. Johnson identified a reverse-coil lead grounding problem on V4ML-12 engines caused by incorrect installation of retaining ring 310416.

Johnson Motors Service Bulletin letterhead

November, 1965

SUBJECT:  GROUNDED REVERSE COIL LEAD

MODELS:   V4ML-12 ENGINES

Factory photograph showing gearcase retaining ring with opening at top

We have found several cases where the reverse coil circuit has been grounded due to fraying of the coil lead. In all cases of malfunctioning reverse systems that we have examined, we have found the retaining ring (P/N 310416) installed with the opening at the bottom side of the gearcase. This allowed the flat edge of the retaining ring to press against the lead, thus fraying the wire.

If for any reason you should disassemble a gearcase, always reinstall the retaining ring with the opening at the top as shown in the illustration. This will eliminate any possibility of a frayed coil lead.

JOHNSON MOTORS

N. Peter Hansen
Administrative Assistant

NOTE: Post on your V4M-100 HP Index under the heading "Lower Unit."

Historical parts reference

310416 - Retaining ring. The factory directs that its opening face upward to avoid contact with the reverse coil lead.