Johnson Service Bulletin SB-1116 - Dual 60 and 80 HP Installations

Issued December 1966, this bulletin explains battery charging considerations when two Johnson outboards with unregulated 6-amp alternators share a single battery. It includes a precaution for prolonged high-speed operation.

Johnson Motors Service Bulletin factory letterhead
SB-1116

December, 1966

SUBJECT:DUAL INSTALLATION OF 60 & 80 H.P. ENGINES
WITH 6 AMP, UNREGULATED ALTERNATORS
ON MODELS:VX-12M & 13, 60 H.P. AND V4S-19, 80 H.P.

When making a dual installation of the subject motors using only one battery, the question will arise as to whether or not the unregulated output of the alternators will burn out the battery.

The maximum, net amperage available at 4500 R.P.M. would exceed 10 amps. With normal stop and start operation, and the use of various accessories, the chances are very few that you would do any harm to the battery.

CAUTIONSUFFICIENT BATTERY WATER LEVEL MUST BE MAINTAINED!
CHECK FREQUENTLY

However, if the condition is such that operation is at sustained high RPM with little or no accessory current draw, we recommend that the alternator be disconnected on one of the motors.

This can be done by simply disconnecting the two yellow stator leads at the connector between the stator and rectifier, and plugging in a dummy, 510684 housing. This housing should then be taped and secured to prohibit the leads from becoming entangled in the flywheel.

JOHNSON MOTORS

Carl Klawonn
Administrative Assistant

CK:rs