Johnson Service Bulletin SB-1157 - Insufficient Torque of Starter Thru Bolts

Issued April 1968 for Johnson TR(L)-10 55 HP engines. Johnson directed dealers to check starter thru-bolt torque on engines built before serial number 2931918 to prevent armature misalignment and starter binding.

Johnson Motors Service Bulletin factory letterhead

April, 1968

SUBJECT: INSUFFICIENT TORQUE OF STARTER THRU BOLTS

ON MODEL: TR(L)-10, 55 H.P.

We have been advised by our Production Department that several 55 horsepower motors were built using starter motors with insufficient torque on the two thru bolts. This condition, if gone unnoticed, will result in an inoperatable starter as the armature will soon become misaligned and hang up.

All 55 horsepower motors built prior to serial #2931918 should be checked for low torque in this area. The correct torque of the nuts on the thru bolts is 57-63 inch pounds.

JOHNSON MOTORS

Carl Klawonn
Administrative Assistant

CK/rkm

Service reference

Models: TR(L)-10, 55 H.P. Serial range: prior to #2931918. Starter thru-bolt nut torque: 57-63 inch-pounds.

Historical factory service information. Verify applicability before performing repairs.