Johnson Service Bulletin SB-1158 - Dual Installation - Transom Mounting

Issued April 1968, this factory bulletin documents Johnson's tested engine-center spacing for dual installations of TR(L)-10 55 HP outboards. It distinguishes the 26-inch industry recommendation from Johnson's tested 22-inch spacing and warns against positioning the motors closer.

Johnson Motors Service Bulletin factory letterhead

April, 1968

SUBJECT:DUAL INSTALLATION - TRANSOM MOUNTING
ON MODEL:TR(L)-10, 55 H.P.

We have found that the 55 horsepower motors can be installed with closer centers than recommended by Boating Industry Association standards. The standard center line distance is 26 inches for dual installation as specified by B.I.A. and stated in the Owner's Manual.

Tests reveal that this distance can be reduced to 22 inches. This distance appears to still leave too much space between the engine; however, if you move them any closer, one lower unit starts affecting the other in turns to cause cavitation.

JOHNSON MOTORS
Carl Klawonn
Carl Klawonn
Administrative Assistant

CK/rkm