April, 1969

There is a very strong possibility that there are many of the subject upper spring retainers in the field that are improperly drilled.
The hole in the retainer is critical since it is the squareness of this hole with the axis that keeps the retainer in the center of the spool and sleeve.
If the upper spring retainer lays to one side of the spool and sleeve, it is conceivable that the hole in the retainer is off. In the event that you happen to have any retainers that are off, you should drill an 11/64" diameter hole through the retainer, as shown in the photo.
Doug Cankar
Administrative Assistant
DC:rm
NOTE: Post on your MQ - 9½ H.P. Index under the heading "Miscellaneous."