Johnson Service Bulletin SB-1209 - Starter Motor Mounting

Issued October 1969, this bulletin sets out a starter mounting bolt-tightening sequence intended to prevent pinion-to-flywheel misalignment. Three footnotes also correct a test-wheel shaft dimension, 85 HP parts catalog entries, and gearcase gasket requirements.

Johnson Motors Service Bulletin factory letterhead

October, 1969

SUBJECT:STARTER MOTOR MOUNTING

ON MODELS:  1968 - 55 H.P.; 1969 - 55 H.P., 85 H.P., and 115 H.P.;
            1970 - 60 H.P., 85 H.P., and 115 H.P.

Due to recent tests, we have developed a correct procedure for mounting the starter motor on the above model engines. The starter motor mounts to the engine through three tabs welded to the starter motor frame. The three mounting bolts should be started. The bolt passing through the single welded tab of the starter motor frame should be tightened securely first. Then, the two remaining bolts on the side with the two tabs should be tightened.

This sequence of tightening the mounting bolts should prevent any possible misalignment of the starter motor on the above model motors.

If a problem of binding or too loose an engagements between the starter motor pinion gear and the flywheel gear exists, the three mounting bolts should be loosened and the above procedure followed.

JOHNSON MOTORS
Doug Cankar
Doug Cankar
Administrative Assistant
FOOTNOTE #1:

On your Johnson outboard test wheel identification chart, test wheel P/N 380757 shows 31/32" diameter shaft; should read 9/16" diameter shaft.

FOOTNOTE #2:

There is a correction needed in your 85 H.P. Parts Catalog on Page 7, Item 1. It reads 383826 and 383827; should read 383928 upper and 383927 lower, respectively.

FOOTNOTE #3:

The Gasket #313765 between the Gearcase and the Exhaust housing of the 1968 - 55 H.P.; 1969 - 55 H.P., 85 H.P., and 115 H.P. is no longer required. If removal of the gearcase becomes necessary, do not install the 313765 Gasket between the exhaust housing and the gearcase.

NOTE:  Post on your 55 H.P., 60 H.P., 85 H.P., and 115 H.P. Indexes under the heading "Electrical".

DC:rm