October, 1969
SUBJECT: GEARCASE SOLENOIDS
ON MODELS: 55 H.P., 60 H.P., 85 H.P. and 115 H.P. with
Hydro-Electric Shift

We have received scattered reports from the field of the following complaints:
a. Twenty amp fuse blown for no apparent reason.
b. Burned out blocking diodes.
c. Solenoids drawing too much current.
d. Won't shift out of forward.
e. Jumps out of neutral or reverse into forward.
In most of these cases we have found the cause to be a defective shift solenoid. We suggest the following test should one of the above symptoms be reported by an owner.
JOHNSON MOTORS, DIVISION OF OUTBOARD MARINE CORPORATION, WAUKEGAN, ILLINOIS 60085
a. Connect a low reading ammeter in series in the neutral solenoid line (dark green). This can be done by opening knife disconnects at rear of lower motor cover.
b. Place gear selector in neutral and turn ignition key on. Leave circuit energized at least ten minutes.
c. Check the amperage draw. It must be between 1.0 and 2.0 amps.
d. Repeat the test on the reverse solenoid using similar test procedure and test values.
If amperage draw in either test is outside the test limits, solenoid is defective and must be replaced.
Doug Cankar
Administrative Assistant
DC:rm
NOTE: Post on your 55 H.P., 60 H.P., 85 H.P. and 115 H.P. Indexes under the heading "Gearcase".