It has been reported that some 50 HP rope motors are developing hard starting problems on damp mornings, particularly in salt water areas. The problem appears to be leakage from Ignition Sensor Assembly to the timer base and shield assembly.
This problem can be checked using the Condenser Tester Leakage Test, outlined in the 55 HP Service Manual, section 4, page 11, “Checking Sensor Coil”. The stop switch circuit should also be checked with both leads disconnected.
After cleaning area with alcohol, apply liberal amount of Gaco to the back of the sensor around leads, between sensor and shield, and to mounting screws. Also apply on stop switch around leads.
The correct resistance for the sensor coils in the 50 HP Rope Start Motor is: 50-62 OHMS.
Service Department