P/N'S 580688, 580730, 580740, 580847, 580833
HIGH PERFORMANCE V-4,
580740 - 1970-72 85, 100, 115, 125 HP
580833 - 1971-73 50 HP & 580847 - 1970-71 60 HP
To improve their performance, a change has been made in the windings of the coils listed above.
We do not feel that the change was drastic enough to require a change in part number; however, we feel a need to inform you how you can determine whether the coils you have in stock are of the former windings or whether they are the improved windings. To check this, measure the resistance between the blue primary lead and the high tension (secondary) lead. If you get a reading of 1300 ± 200 ohms, it is the improved winding. If you get a reading of 1900 ohms, it is the former winding.
If your coils have the new windings, use the test specifications listed below.
IGNITION COIL TEST
SPECIFICATIONS
| Stevens Model ST-75 | |
|---|---|
| Reverse Polarity (Switch Setting CD) | 1.9 |
| Stevens Tester Model M.A. -75 or M.A. -80 | |
| Switch **A | Index Adjustment 20 |
| **Use Model CD-1 Adaptor Red test clip to orange/black Black test clip to orange | |
| Merc-O-Tronic with Capacitor Discharge Adapter Model 55-980 | ||
|---|---|---|
| Operating Amperage Min. - Max. | Primary Resistance Min. - Max. | Secondary Continuity Min. - Max. |
| 1.9 | .1 Ohm | 8 - 20 |
Graham Tester Model 51
Hi tension lead disconnected)
If you have coils with the old windings follow your normal procedure outlined in the appropriate service manual.
The performance of the motor will be the same with either coil, only the test procedures are affected.
It is absolutely necessary that you follow this procedure so you are not mislead by the readings you receive during your troubleshooting process.
Service Department