Johnson Service Bulletin SB-1380 - Stator Resistance Readings
Issued March 1975, this bulletin compares coated and molded stator resistance specifications on 1974-1975 Johnson 50 through 135 H.P. outboards.

SB-#1380
March, 1975
SUBJECT: Stator Resistance Readings
ON MODELS: 1974 thru 1975 50 thru 135 H.P.
1974 and 1975 50 through 135 H.P. engines may have either a
coated type stator (coils are visible) or a molded type sta-
tor (coils are not visible). While the coated type is inter-
changeable with the molded stator, the resistance readings
for each are different.
Refer to the chart below when testing a stator.

JOHNSON OUTBOARDS
W. R. Scheske
Manager, Technical Services
Searchable stator resistance specifications
The original factory chart is reproduced above. Values below are transcribed for searching; consult the original chart when performing measurements.
| Horsepower | Output | Coated charge coil | Coated alternator coil | Molded charge coil | Molded alternator coil |
|---|---|---|---|---|---|
| 50 H.P. | 6 Amp | 875 ±75 ohms | 1.3 ±.3 ohms | 750 ±75 ohms | 1.3 ±.3 ohms |
| 50 H.P. | 12 Amp | 860 ±75 ohms | .2 ±.05 ohms | Not built | Not built |
| 70-75 H.P. | 6 Amp | 875 ±75 ohms | .9 ±.3 ohms | 630 ±75 ohms | .9 ±.3 ohms |
| 70-75 H.P. | 12 Amp | 870 ±75 ohms | .3 ±.05 ohms | Not built | Not built |
| 85, 115, 135 H.P. | 6 Amp | 900 ±75 ohms | 1.2 ±.3 ohms | 630 ±75 ohms | 1.2 ±.3 ohms |
| 85, 115, 135 H.P. | 12 Amp | 860 ±75 ohms | .2 ±.05 ohms | Not built | Not built |
Related topic: stator charge coil overheating and alternator troubleshooting, SB-1370.