Johnson Service Bulletin SB-1427 - Permanently Installed Fuel Systems
August 1976 factory recommendations for built-in fuel systems on high-horsepower Johnson outboard installations.

August, 1976
SUBJECT: Permanently Installed Fuel Systems
ON MODELS: Dual V-4 or Single or Dual V-6
With the coming of larger outboard motors, we anticipate the need for information concerning permanently installed fuel systems. The following recommendations are intended as a design guide for built-in fuel systems on boats using Johnson outboard motors of more than 150 total horsepower (e.g. dual V-4 or single V-6 installations). Adhering to these recommendations will insure adequate fuel supply.
TANK PICKUP TUBE - Should be minimum 5/16" I.D. - 3/8" I.D. is preferred.
PICKUP TUBE SCREEN - Recommend stainless steel #304 wire cloth, 100 X 90 mesh, .0045 diameter wire with a total open area not less than .170 square inches.
ANTI-SIPHON VALVE - Anti-siphon valves should have a pressure drop of no more than 35 inches (maximum) of water at a fuel flow rate of 20 gallons per hour. The following OMC valves which meet the above criteria are available.
#173273 for 5/16" I.D. Hose
#173274 for 3/8" I.D. Hose
#173275 for 3/8" O.D. Copper Tube
FUEL DISTRIBUTION LINES (From Tank to Drywell Fitting) - Minimum 5/16" I.D. (3/8" I.D. preferred). OMC #319719 hose (5/16" I.D.) or OMC #123111 (3/8" I.D.) lengths. All fittings must be a minimum of 1/4" I.D. Be sure lines are free of kinks and sharp bends.
FILTER - If a fuel filter is installed, it should have no more than five inches of water pressure drop at a fuel flow rate of 20 gallons per hour. The filter should have a minimum filter area of 200 square inches. The OMC #173319 filter meets the foregoing criteria. Nipple kits #173311 (5/16" I.D.) and #173312 (3/8" I.D.) may be used to adapt filter to flexible hose. DO NOT use OMC #377381 primer kit if motors of over 150 H.P. total are installed.
FUEL LINE (From Drywell Fitting to Engine) - OMC hose primer bulb and connector assembly #173277, is available for connecting from a bulkhead fitting in the drywell to the engine.
JOHNSON OUTBOARDS, DIVISION OF OUTBOARD MARINE CORPORATION, WAUKEGAN, ILLINOIS 60085
DUAL V-6 INSTALLATION - Two separate fuel lines, as described above, including two pick ups are recommended for a twin V-6 installation. This is also recommended as the best way to install twin V-4's. Although a single line split at the motor will work, it may be marginal under certain conditions.
GENERAL - A good pipe thread sealant should be used at all threaded connections.
IMPORTANT NOTE - We recommend that ABYC standard H-24 and BIA standard 144-75 be followed to provide a safe installation for the entire built-in fuel system. For further information review Service Bulletin #1392.

D. J. Leinonen
Technical Data Coordinator
DJL/kr
NOTE: Post on your 85 h.p. thru V-6 bulletin indexes under heading "Carburetion".
Related factory information
SB-1392 is referenced for additional built-in fuel system guidance. The bulletin also cites ABYC H-24 and BIA 144-75.