OMC Service Bulletin No. 2013: Overheating - How to Prevent Water Pump Air Lock

Issued November, 1980, this gearcase bulletin addresses overheating - how to prevent water pump air lock for 1976 Thru 1981, 35 (Plastic Pump Only).

OMC Outboard Service Bulletin
Gearcase

No. 2013
November, 1980

Subject:   Overheating - How to Prevent Water Pump Air Lock

Models:   1976 Thru 1981, 35 (Plastic Pump Only)

The 35 model water pump can become air locked under certain conditions. If the water inlet openings are allowed to clear the water while the engine is running and the outlet water pressure drops to zero, when the inlets are submerged again and the engine operated in reverse, the pump may not re-prime.

This modification can be made to all plastic 35 model water pump housings. This condition can be corrected by drilling a 1/16 inch (1.6 mm) diameter hole in the water pump housing as shown below.

Water pump housing drilling location and dimensions

Hole should be in line with center of shift rod guide hole and aimed at and aligned with center of water tube tower. Hole must clear bottom of water tube grommet.