OMC blocking diode location and measurement chart for outboards with the S.L.O.W. overheat warning system.

Locating the blocking diode
The blocking diode is in the motor’s electrical cable, connected to the TAN or YELLOW/RED wires.
To find the blocking diode for servicing, measure according to the chart below, its footnotes, and the illustrations. Instructions for diode replacement are provided in the repair kit.

| Model | Year | Type of Connector | Distance From Edge of Connector Ⓐ |
|---|---|---|---|
| 20-30 | 1989 and newer | Red | 2” (50.8 mm) |
| 40-50 | 1989 and newer | Red | 2¾” (69.9 mm) |
| 45WML | 1989 and newer | Red | 4½” (114.3 mm) |
| 40TTL | 1990 and newer | 4 wire | 4” (101.6 mm) |
| 60TTL/70TTL† | 1989 thru 1991 | 3 or 4 wire | 3¼” (82.6 mm) & 4” (101.6 mm) |
| 60/70 | 1989 and newer | Red | 5” (127 mm) |
| 85TTL | 1991 models only | * | |
| 120/140 | 1988 and newer | Red | 19¾” (501.7 mm) |
| 150/175 - 90° | 1989 and newer | Red | 16” (406.4 mm) |
| 150/175 - 60° | 1991 and newer | Red | 5½” (139.7 mm) |
| 200/225 | 1988 and newer | Red | 24½” (609.6 mm) |
| V8 | 1988 and newer | Red | 29¼” (743 mm) |
† These models have two diodes. From the connector, measure the TAN wires 3¼” (82.6 mm) - measure the YELLOW/RED wire 4” (101.6 mm).
* Measure 9¼” (235 mm) from the RING TERMINAL on the yellow/red wire at the starter solenoid.