Problem: There is a new horn driver for installations where an OMC System Check gauge is not required. The new horn driver looks different than the original horn drivers, and it has different requirements to interface with the OMC Modular Wiring System.
Solution:
1 The new Horn Driver Ⓐ, P/N 176794, is in a flat case. There is no warning horn in this new case as there was in the original horn driver Ⓑ. A separate warning horn MUST BE USED with the new horn driver.
2 When the new horn driver is used, the original horn Ⓒ, or Horn Kit, P/N 176361, must be connected to the 2-wire Deutsch® plug Ⓓ, on the instrument harness.
The new horn driver produces the same warning signals as the old horn driver.
The horn driver must be installed vertically in the driest available location, such as under the dash for remote models. For tiller models it must be partially enclosed, or a rain and splash shield placed over it. Use OMC Electrical Grease on the Deutsch plug.