Johnson Service Bulletin SB-1031 - Automatic Choke & Override - 90 HP

September 23, 1964. Johnson factory instructions for inspecting the automatic choke override linkage on 90 HP engines, including the choke arm, set screw, and nylon bushing.

Johnson Motors gray service bulletin header
SB-1031
September 23, 1964
SUBJECT: AUTOMATIC CHOKE & OVERRIDE - 90 HP.
If any difficulty is encountered in starting the 90 HP motors, when motor is hot or cold, check to make sure the arm, part number 308882, which connects the choke shaft to the choke override solenoid spring and plun- ger is still in place. We have had a few cases where this arm has vibrated off the end of the shaft.
This prevents the functioning of the electric choke and the override; thus, during starting when engine is hot, the automatic choke remains in the choke off position, whereas normally, the solenoid closes the choke when key is in start position.
We have found that the set screw which locks the arm to the choke shaft is not sufficiently tight. We would recommend that you check and tighten the set screw on any 90 HP models which you have in stock and any that come in for servicing to prevent future complaints. There is a nylon bushing on the choke shaft above the arm. Be sure this is in position.
Sincerely,
JOHNSON MOTORS Robert Compton Administrative Assistant
RC/ll
NOTE: Post on VM-90HP Index under "CARBURETOR".