SB-1031
September 23, 1964
SUBJECT: AUTOMATIC CHOKE & OVERRIDE - 90 HP.
If any difficulty is encountered in starting the 90 HP motors, when motor
is hot or cold, check to make sure the arm, part number 308882, which
connects the choke shaft to the choke override solenoid spring and plun-
ger is still in place. We have had a few cases where this arm has
vibrated off the end of the shaft.
This prevents the functioning of the electric choke and the override;
thus, during starting when engine is hot, the automatic choke remains in
the choke off position, whereas normally, the solenoid closes the choke
when key is in start position.
We have found that the set screw which locks the arm to the choke shaft
is not sufficiently tight. We would recommend that you check and tighten
the set screw on any 90 HP models which you have in stock and any that
come in for servicing to prevent future complaints. There is a nylon
bushing on the choke shaft above the arm. Be sure this is in position.
Sincerely,
JOHNSON MOTORS
Robert Compton
Administrative Assistant
RC/ll
NOTE: Post on VM-90HP Index under "CARBURETOR".