Johnson Service Bulletin SB-1036 - Erratic Shifting

Issued December 2, 1964, this factory bulletin describes a possible electrical cable insulation failure caused by the mounting clamp on 1964 75 and 90 HP Electramatic Shift outboards. The original bulletin is reproduced below with searchable text and its two factory photographs.

Johnson Motors Service Bulletin letterhead

December 2, 1964

SUBJECT:  ERRATIC SHIFTING - 1964 ENGINES.

ON MODELS:  Electramatic Shift 75 & 90 HP.

We have received reports of motors jumping in and out of gear or experiencing momentary ignition cut off, or the hot light coming on while advancing the throttle.

These problems have been traced in some cases to a short circuit caused by the cable clamp (Figure 1) part no. 310439.

Figure 1 - cable clamp number 310439 installed on engineFigure 2 - damaged electrical cable insulation

As the electric cable is clamped in a stationary position to the lower motor cover, the fore and aft movement of the powerhead under thrust allows the clamp if improperly positioned to cut the insulation of the cable (Figure 2).

We suggest you remove the cable from the cable clamp and inspect it carefully.  If any of the above problems are encountered, use electrical tape to reinsulate the cable.

Sincerely,

JOHNSON MOTORS
Robert Compton
Administrative Assistant

RC/ll

NOTE:  Post on V4-75 HP and VM-90 HP indexes under "ELECTRICAL".

     DESTROY DUPLICATED BULLETIN NO. SB #1032, DATED OCTOBER 14, 1964.

Historical reference

Duplicate bulletin notice: This document calls for destruction of a duplicated SB-1032 dated October 14, 1964. This is distinct from the October 1, 1964 SB-1032 - Shifter Dog Failures.

Part reference: 310439 - electric cable clamp.