September 12, 1966 SB #1106
SUBJECT: TANK TESTING THE 1967-40 H.P. MOTORS
ON MODELS: RD and RDS-29 - 40 H.P.
Whenever running one of the subject motors in a test tank for any purpose, strict adherence to the following is necessary to avoid overheating:
- Install a test tank adaptor to the water intake. (Fig. 1)
- Regulate the water line pressure to the adaptor to 3 to 5 P.S.I.
- Maintain test tank water level to within 13 inches of the top face of the test tank mounting bracket. (Fig. 2)


The adaptor used in the above illustration is manufactured by Tempo Products and will be listed in our Special Tool catalog under part number 382107. It is available through our Parts Depot at Galesburg, Illinois. This is a net item at $3.50 each and must be prepaid.
Carl Klawonn
Administrative Assistant
NOTE: Post on your RD and RDS-40 H.P. Indexes under the heading "Miscellaneous".