Johnson Service Bulletin SB-1176 - Operating C.D. Ignition Engines with Stevens' Junction Box

Issued December 1968, this bulletin explains test-tank precautions for capacitor-discharge ignition engines, including resistor bypass, alternator stator-lead disconnection, and battery voltage.

Johnson Motors Service Bulletin factory letterhead

December, 1968

SUBJECT:OPERATING C.D. IGNITION ENGINES WITH
STEVENS' JUNCTION BOX

If you are using the Stevens' Junction Box for tank testing engines equipped with Capacitive Discharge ignition, please take special note of this bulletin.

Stevens' S-28 Junction Box has a built-in resistor in the ignition circuit for operating battery ignition models and this resistor must be bypassed for models with C.D. ignition. If not, the engine will run erratic and miss at high R.P.M. due to the drop in voltage.

As the 1967 100 horsepower models became available, Stevens set up special instructions for operating these models. You should have automatically received a copy of these instructions from Stevens. If not, request them from: Stevens Experimental Company, 2015 Grand Avenue, Waukegan, Illinois 60085.

For 1968, Stevens made available an Adaptor (SA-68) for the junction box to facilitate operation of 1968 33 through 100 horsepower models. This Adaptor requires fewer individual connections at the motor simplifying its use. (See Service Promotion Bulletin SPB-408 for further details.)

Of particular note, whenever using the Stevens Junction Box, it is imperative that the stator leads be disconnected on models with magnet energized alternators, whether or not tests are simultaneously made on the alternator components.

By leaving the stator leads hooked up, immediate damage to the rectifier will occur. This resultant damage can soon cause failure of the Pulse Pack or Amplifier.

Through constant use of the Stevens' equipment, your test tank battery will run down. Such a condition will also cause damage to the Prestolite Pulse Pack. Although the engine may start and run O.K., battery voltage less than 11 volts causes damage to the Pulse Pack in a very short time. Keep your test tank battery fully charged at all times.

JOHNSON MOTORS Carl Klawonn Administrative Assistant

CK:rm

NOTE:  Post on your Miscellaneous Index under the heading "Test Equipment."

Related bulletin

SPB-408 - Stevens SA-68 junction-box adapter for 1968 engines, referenced by SB-1176.