SUBJECT: AUTOMATIC CHOKE ADJUSTMENT FOR WARM CLIMATE OPERATION.
ENGINES: 90 HP, MODELS V4M (L) - 10S
Our Engineering Department has advised that the 90 HP automatic choke should be adjusted between three to five notches leaner for operation in warm climates. This will permit easier starting, will eliminate much of the smoke that is present during warm-up if the original factory setting is overchoking the engine and will improve overall operation of the engine at slower speeds during the warm-up period.
Make Adjustment as follows:
- Before disturbing original factory setting, scribe a mark along the lean (L) side of the indexed quadrant. This line will later serve as a reference to the original setting once the quadrant is moved.
- Loosen set screw A (Fig. 1) and adjust the quadrant approximately three to five notches leaner. The precise amount of adjustment will vary minutely depending on temperature variations and also from one engine to another; however, in a number of engines checked at the Florida testing station, all engines could be set somewhere between three to five notches lean for optimum performance.

3. Tighten set screw A and check operation of choke under normal running conditions.
JOHNSON MOTORS
Robert Compton
RC:eb
NOTE: Post on your VM-90 HP index under the heading of "Carburetion".
P.S. When viewed from above, the indexed quadrant is turned counterclockwise to affect a leaner choke setting and turned clockwise to affect a richer choke setting.