June, 1967
SUBJECT: SELF-STARTING 100 H.P. MODELS WITH
POWER PULSE IGNITION
ON MODELS: V4T(L)-13
It is possible that POWER PULSE equipped 100 H.P. models, at normal operating temperatures, will occasionally start themselves when the ignition key is turned to the "ON" position within a minute after shutting them off.
The condenser requires a short time to bleed down after the ignition is turned off and self-starting can occur at any time prior to completion of the condenser bleed down, providing the Sensor Rotor is in correct position relative to the Sensor.
Be sure all service personnel and others who may have occasion to activate the ignition system in this manner are aware of the possibility of self-starting. In the interest of safety, we recommend the Pulse Transformer output lead or spark plug leads be grounded, whenever possible, when checking the ignition system.
CK/rkm
NOTE: Post on your V4M 100 H.P. Index under the heading
"Ignition".