Johnson Service Bulletin SB-1133 - Self-Starting 100 H.P. Models with Power Pulse Ignition

Issued June 1967, this bulletin warns that certain 100 HP Johnson outboards can start unexpectedly after shutdown if the ignition key is returned to ON. The historical factory safety instructions are reproduced below.

Johnson Motors Service Bulletin factory letterhead

June, 1967

SUBJECT:   SELF-STARTING 100 H.P. MODELS WITH
              POWER PULSE IGNITION

ON MODELS:   V4T(L)-13

It is possible that POWER PULSE equipped 100 H.P. models, at normal operating temperatures, will occasionally start themselves when the ignition key is turned to the "ON" position within a minute after shutting them off.

The condenser requires a short time to bleed down after the ignition is turned off and self-starting can occur at any time prior to completion of the condenser bleed down, providing the Sensor Rotor is in correct position relative to the Sensor.

Be sure all service personnel and others who may have occasion to activate the ignition system in this manner are aware of the possibility of self-starting. In the interest of safety, we recommend the Pulse Transformer output lead or spark plug leads be grounded, whenever possible, when checking the ignition system.

JOHNSON MOTORS
Carl Klawonn
Administrative Assistant

CK/rkm

NOTE:   Post on your V4M 100 H.P. Index under the heading
        "Ignition".

Historical reference

SB-1133 applies to V4T(L)-13 100 H.P. Power Pulse ignition engines. The warning describes a possible unintended engine start after shutdown. This reproduction preserves the original factory guidance; consult appropriate current safety procedures before servicing ignition equipment.